Protection&Control Transmission Line Protection Busbar Protection Transformer Protection Circuit Breaker Protection Generator Protection Feeder Protection Capacitor Protection Motor Protection Transfer & Synchronization Arc Protection
Digital Substation PCS-221S Merging Unit PCS-221 Merging Unit PCS-222 Circuit Breaker Controller PCS-9250 AC Electronic CT/VT
Automation PCS-9700 Automation System PCS-9700 HMI Software PCS-9705 Bay Control Unit PCS-9705S Bay Control Unit PCS-9799 Station Manager PCS-9799S Station Manager PCS-9710 Remote Terminal Unit PCS-9710S Remote Terminal Unit PCS-9794 Protocol Converter PCS-9785 Satellite-Synchronized Clock PCS-9882 Ethernet Switch PCS-9882Rx DIN Rail Managed Ethernet Switch PCS-9882XD Managed Ethernet Switch PCS-9884 Managed Ethernet Switch Supporting HSR and PRP MUX-2M/64 Communication Interface
Phasor Measurement PCS-997S Fault Line Locator PCS-996S-G Phasor Data Concentrator PCS-996 Phasor Measurement Unit
Disturbance Fault Recording PCS-996RC Disturbance Fault Recorder PCS-996R Disturbance Fault Recorder PCS-986 Disturbance Fault Recorder PCS-9013 DFR Management System
Stability Control System PCS-992 Power Stability Control System PCS-993 Out-of-Step Controller PCS-994 Frequency & Voltage Controller PCS-994S Frequency and Voltage Controller
Power Grid Monitoring and Control PCS-9000 Energy Management System PCS-9000 Distribution Management System
Configuration Tool PCS-Torch MOT Tool PCS-Studio Configuration Tool PCS-Explorer IED Configuration & Debugging Tool PCS-SCD Configuration Tool PCS-COMM Configuration & Debugging Tool
Accessories MD1501 Series Auxiliary Relays MD1701 Series Test Blocks MD1701S Test Block
FACTS PCS-9580 Static Var Compensator PCS-9583 Static Synchronous Compensator PCS-9570 Series Compensation PCS-9590 DC De-Icer PCS-9578 Controllable Shunt Reactor PCS-8200 Unified Power Flow Controller PCS-9571 Fault Current Limiter PCS-9564A Dynamic Voltage Restorer PCS-9569 Shore Power System
HVDC PCS-8600 UHVDC Converter Valve System PCS-9550 LCC-HVDC Control and Protection System PCS-8100 VSC-HVDC IGBT Valve PCS-9520 VSC-HVDC Control and Protection System PCS-9510 Cooling System PCS-8300 High-voltage DC Circuit Breaker PCS-9250 DC Electronic CT/VT
PV & Wind Power Grid-Connection PCS-9700 Renewable Energy SCADA PCS-9726 Generation Management Unit PCS-9700F Power Forecast System PCS-9700R AGC/AVC
Battery Energy Storage System PCS-9567MV-10000 Medium Voltage Skid PCS-9567MV-7000 Medium Voltage Skid PCS-9567MV-5000 Medium Voltage Skid PCS-9567MV-3500 Medium Voltage Skid PCS-9567-2500 Twin Power Conversion Systems PCS-9567-1750 Power Conversion System PCS-9567-1750 電力変換システム PCS-9567 Power Conversion System Vulnerability Disclosure Policy PCS-9567 パワーコンディショナー脆弱性開示ポリシー
Microgrid PCS-9617MG Microgrid Controller
Static Frequency Converter PCS-9575 Static Frequency Converter
Protection,Automation&Control DMS EMS Stability Control & WAMS Digital Substation
HVDC & FACTS De-Icing Unified Power Flow Controller (UPFC) Series Compensation Static Synchronous Compensator(STATCOM) Static Var Compensator (SVC) LCC-HVDC Transmission VSC-HVDC Transmission
Renewable & Microgrid Energy Storage System Microgrid PV Generation SFC
Power Generation Pumped Storage Power Plant Nuclear Power Plant Hydro Power Plant Thermal Power Plant
Transmission System AC Transmission LCC-HVDC Transmission VSC-HVDC Transmission
Distribution System Distribution Network
Industrial Consumer Urban Track Traffic Electrified Railway Oil & Petrochemical Metals & Mining
HOME PRODUCTS Renewable & Microgrid Battery Energy Storage System
NEWS
EVENT CALENDOR
CONTACT US
1. Introduction
NR Electric Co., Ltd. (hereinafter "the Company") formulates this summary to clarify core operation, maintenance and safety info of the PCS-9567, helping personnel grasp essentials for safe, stable equipment operation.
2. Scope
Applies to the Company’s PCS-9567 Power Conversion System, covering product overview, core functions, operation procedures, maintenance and safety precautions.
3. Product Overview
- Core Function: Acts as a flexible interface between energy storage units and the grid, enabling bidirectional AC/DC energy flow via integrated charging/discharging design.
- Key Parameters: DC voltage 1050~1500V, nominal AC output 1750kVA, max altitude 5000m (derating >3000m), operating temp -40~60℃ (derating >45℃), IP65 protection, forced air cooling, transformerless isolation.
- Compatibility: Supports lithium-ion, sodium-ion, lead-acid and lead-carbon batteries.
4. Core Functions
- Charging/Discharging Control: Supports constant current/voltage/power modes; auto-switches to constant voltage at charge/discharge end.
- Dual Modes: Free switch between "grid-following" (bidirectional grid energy exchange) and "grid-forming" (simulates virtual synchronous generator for isolated grid support).
- Grid Regulation: Impact-free soft grid-connection (THD <3%); coordinates with AGC/PMS for frequency regulation, AVC for reactive power/voltage control.
- Protection & Recording: Comprehensive protections (overvoltage/undervoltage/overcurrent/over-temperature/islanding/communication failure); fault recording in COMTRADE format.
- Communication: CAN/RS-485/RJ45/optical fiber ports; supports Modbus/IEC 61850/IEC 60870-5-103/GOOSE, delay <2ms.
5. Operation Procedures
- Grid-Following Startup: Power on upstream transformer → Close 1K MCB → Turn on NR1301 power → Power on battery → Close DC switch via EMS → Confirm no alarms/grid conditions met → Start PCS.
- Grid-Following Shutdown: Stop PCS via EMS → Open DC switch (confirm voltage 0) → Power off battery → Turn off 1K MCB → Trip HV breaker.
- Emergency Stop: Press "EMERGENCY STOP" button (for emergencies only).
6. Maintenance Requirements
- Preventive: Weekly (appearance, LEDs, air inlets/outlets); monthly (fixation, grounding); clean filters regularly; twice-yearly comprehensive check (clean components, cable insulation, grounding resistance).
- Fault Handling: Stop equipment/power off → Check components (modules, sensors, cables) per prompts; contact after-sales for unrepairable faults.
7. Safety Precautions
- Personnel: Only certified personnel allowed; trained in safety ops, first aid and safety gear (shoes, gloves, glasses, head protection) use.
- Electrical: No touch on energized terminals (DC voltage remains post-power-off); no PCB plug/unplug when energized; separate power/communication cables.
- Operation: No unauthorized parameter modification; no arbitrary AC/DC switch disconnection; no long-term overload.
8. Manufacturer Information
- Headquarters: 69, Suyuan Avenue, Jiangning, Nanjing 211102, China
- Manufactory: 18, Xinfeng Road, Jiangning, Nanjing 211111, China
- Contacts: Tel: +86-25-87178888; Fax: +86-25-87178999; Website: www.nrec.com/en