PCS-902S Line Distance Relay
  • PCS-902S line distance relay integrates main and back-up protection functions, which is designed for overhead line, cables and hybrid transmission lines of  various voltage levels and provides comprehensive protection and control solutions. With its flexibility and the powerful PCS-Studio configuration tool, PCS-902S offers future-oriented system solutions with high investment security and low operating costs.


  • Protection and Control Synchrophasor measurement Measurement Recording Supervision Communication interface Pilot channel scheme Communication protocol Digital application Clock synchronization
    • High-speed DPFC distance protection (21D)

    • Six zone phase-to-phase distance protection (21L)

    • Six zone phase-to-ground distance protection (21L)

    • Pilot distance protection (85)

    • Pilot directional earth-fault protection (85)

    • Unique power swing blocking releasing logic (PSBR)

    • Six stages phase overcurrent protection (67P, 50/51P)

    • Six stages earth-fault protection (67G, 50/51G)

    • Two stages negative-sequence overcurrent protection (67Q, 50/51Q)

    • Switch-onto-fault (SOTF) logic

    • Two stages phase undervoltage protection (27P)

    • Two stages phase overvoltage protection (59P)

    • Two stages negative-sequence overvoltage protection (59Q)

    • Two stages residual overvoltage protection (59G)

    • Four stages overfrequency protection (81O)

    • Four stages underfrequency protection (81U)

    • Four stages frequency rate-of-change protection (81R)

    • Two stages reverse power protection (32R)

    • Two stages thermal overload protection (49P)

    • One stage undercurrent protection (37)

    • Breaker failure protection (50BF)

    • Dead zone protection (50DZ)

    • Broken conductor protection (46BC)

    • Pole discrepancy protection (62PD)

    • Stub differential protection (87STB)

    • Out-of-step protection (78)

    • Auto-reclosing (79)

    • Switchgear control

    • Synchronism Check (25)

    • Voltage selection

    • Voltage and current drift auto adjustment

    • Single-ended impedance-based fault location


    • Synchronize with the GPS time by IRIG-B time source

    • Calculate synchronized phasors, including: Ua, Ub, Uc, U1, U2, U0, Ia, Ib, Ic, I1, I2, I0

    • Calculate analog values, including: active power (P), reactive power (Q), frequency, ROCOF (df/dt)

    • Transmit binary status of the IED to PDC (Phasor Data Concentrator) according to IEEE C37.118 standard

    • Realize high accurate measurement of the phasors and analogues according to the IEEE C37.118.1-2011 and IEEE C37.118.1a-2014 standard.

    • Communicate with PDC according to IEEE C37.118-2005 and IEEE C37.118.2-2011


    • Current and voltage measurement at a 2.4KHz sampling rate

    • Current and voltage measurement at a 9.6KHz sampling rate

    • Energy metering (active and reactive energy are calculated in import respectively export direction)

    • Power (Apparent/Real/Reactive)

    • Power factor

    • Frequency


    • Event Recorder including 1024 disturbance records, 1024 binary events, 1024 supervision events, 256 control logs and 1024 device logs.

    • 64 disturbance waveforms records (The file format of disturbance recorder is compatible with international COMTRADE file.)

    • 64 high-frequency waveforms records (The file format of disturbance recorder is compatible with international COMTRADE file.)


    • CT circuit failure supervision

    • VT circuit failure supervision

    • Trip/Close coil supervision

    • Self diagnostic

    • Pilot communication channel supervision

    • DC power supply supervision

    • Channel status statistic

    • System frequency supervision


    • 2 or 4 100Base-TX copper Ethernet ports for SCADA communication

    • 2 or 4 100Base-FX optical Ethernet ports for SCADA communication

    • 2 RS-485 serial ports for SCADA communication

    • 1 RS-485 serial port for clock synchronization

    • 1 TTL serial port for clock synchronization

    • 1 BNC port for clock synchronization

    • 1 front RJ-45 port for debugging

    • 1 rear RJ-45 port for debugging


    • Optional single- or dual- pilot channels (fiber optic)

    • Support G.703 and C37.94


    • IEC 61850 Editions 1 and 2

    • IEC 60870-5-103

    • DNP3.0

    • Modbus

    • IEC 62439 Parallel Redundancy Protocol (PRP)

    • IEC 62439 High-availability Seamless Redundancy (HSR)

    • IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)


    • IEC 61850 MMS Server

    • IEC 61850-8-1 GOOSE

    • IEC 61850-9-2LE SV

    • 4 100Base-TX electrical or 100Base-FX optical Ethernet port (station level)

    • Extendable 100Base-FX optical Ethernet port (process level)


    • IRIG-B: IRIG-B via RS-485 differential level, TTL level or BNC

    • PPS: Pulse per second (PPS) via RS-485 differential level, binary input or BNC

    • IEEE 1588: Clock message based on IEEE 1588 via Ethernet network

    • SNTP: Unicast (point-to-point) & Broadcast SNTP mode via Ethernet network

    • Clock messages: IEC 60870-5-103 protocol, Modbus protocol and DNP3.0 protocol


    Previous:PCS-902 Line Distance Protection Next:PCS-931 Line Differential Relay Back to list

    © Copyright NR Electric Co., Ltd.
    2001-2020. All Rights Reserved.

    About us Service & Support Company Training Contact Us

    Solutions Power Generation Transmission System Distribution Network Industrial Consumer

    Products Protection,Automation&Control FACTS HVDC Renewable & Microgrid