Protection&Control Transmission Line Protection Busbar Protection Transformer Protection Circuit Breaker Protection Generator Protection Feeder Protection Capacitor Protection Motor Protection Transfer & Synchronization Arc Protection
Digital Substation PCS-221S Merging Unit PCS-221 Merging Unit PCS-222 Circuit Breaker Controller PCS-9250 AC Electronic CT/VT
Automation PCS-9700 Automation System PCS-9700 HMI Software PCS-9705 Bay Control Unit PCS-9705S Bay Control Unit PCS-9799 Station Manager PCS-9799S Station Manager PCS-9710 Remote Terminal Unit PCS-9710S Remote Terminal Unit PCS-9794 Protocol Converter PCS-9785 Satellite-Synchronized Clock PCS-9882 Ethernet Switch PCS-9882Rx DIN Rail Managed Ethernet Switch PCS-9882XD Managed Ethernet Switch PCS-9884 Managed Ethernet Switch Supporting HSR and PRP MUX-2M/64 Communication Interface
Phasor Measurement PCS-997S Fault Line Locator PCS-996S-G Phasor Data Concentrator PCS-996 Phasor Measurement Unit
Disturbance Fault Recording PCS-996RC Disturbance Fault Recorder PCS-996R Disturbance Fault Recorder PCS-986 Disturbance Fault Recorder PCS-9013 DFR Management System
Stability Control System PCS-992 Power Stability Control System PCS-993 Out-of-Step Controller PCS-994 Frequency & Voltage Controller PCS-994S Frequency and Voltage Controller
Power Grid Monitoring and Control PCS-9000 Energy Management System PCS-9000 Distribution Management System
Configuration Tool PCS-Torch MOT Tool PCS-Studio Configuration Tool PCS-Explorer IED Configuration & Debugging Tool PCS-SCD Configuration Tool PCS-COMM Configuration & Debugging Tool
Accessories MD1501 Series Auxiliary Relays MD1701 Series Test Blocks MD1701S Test Block
FACTS PCS-9580 Static Var Compensator PCS-9583 Static Synchronous Compensator PCS-9570 Series Compensation PCS-9590 DC De-Icer PCS-9578 Controllable Shunt Reactor PCS-8200 Unified Power Flow Controller PCS-9571 Fault Current Limiter PCS-9564A Dynamic Voltage Restorer PCS-9569 Shore Power System
HVDC PCS-8600 UHVDC Converter Valve System PCS-9550 LCC-HVDC Control and Protection System PCS-8100 VSC-HVDC IGBT Valve PCS-9520 VSC-HVDC Control and Protection System PCS-9510 Cooling System PCS-8300 High-voltage DC Circuit Breaker PCS-9250 DC Electronic CT/VT
PV & Wind Power Grid-Connection PCS-9700 Renewable Energy SCADA PCS-9726 Generation Management Unit PCS-9700F Power Forecast System PCS-9700R AGC/AVC
Battery Energy Storage System PCS-9567MV-10000 Medium Voltage Skid PCS-9567MV-7000 Medium Voltage Skid PCS-9567MV-5000 Medium Voltage Skid PCS-9567MV-3500 Medium Voltage Skid PCS-9567-2500 Twin Power Conversion Systems PCS-9567-2500 電力変換システム PCS-9567-1750 Power Conversion System PCS-9567-1750 電力変換システム PCS-9567 Power Conversion System Vulnerability Disclosure Policy パワーコンディショナー脆弱性開示ポリシー
Microgrid PCS-9617MG Microgrid Controller
Static Frequency Converter PCS-9575 Static Frequency Converter
Protection,Automation&Control DMS EMS Stability Control & WAMS Digital Substation
HVDC & FACTS De-Icing Unified Power Flow Controller (UPFC) Series Compensation Static Synchronous Compensator(STATCOM) Static Var Compensator (SVC) LCC-HVDC Transmission VSC-HVDC Transmission
Renewable & Microgrid Energy Storage System Microgrid PV Generation SFC
Power Generation Pumped Storage Power Plant Nuclear Power Plant Hydro Power Plant Thermal Power Plant
Transmission System AC Transmission LCC-HVDC Transmission VSC-HVDC Transmission
Distribution System Distribution Network
Industrial Consumer Urban Track Traffic Electrified Railway Oil & Petrochemical Metals & Mining
HOME PRODUCTS Renewable & Microgrid Battery Energy Storage System
1. Introduction
NR Electric Co., Ltd. (hereinafter "the Company") formulates this summary to clarify core operation, maintenance and safety info of the PCS-9567, helping personnel grasp essentials for safe, stable equipment operation.
2. Scope
Applies to the Company’s PCS-9567 Power Conversion System, covering product overview, core functions, operation procedures, maintenance and safety precautions.
3. Product Overview
- Core Function: Acts as a flexible interface between energy storage units and the grid, enabling bidirectional AC/DC energy flow via integrated charging/discharging design.
- Key Parameters: DC voltage 1050~1500V, nominal AC output 1750kVA, max altitude 5000m (derating >3000m), operating temp -40~60℃ (derating >45℃), IP65 protection, forced air cooling, transformerless isolation.
- Compatibility: Supports lithium-ion, sodium-ion, lead-acid and lead-carbon batteries.
4. Core Functions
- Charging/Discharging Control: Supports constant current/voltage/power modes; auto-switches to constant voltage at charge/discharge end.
- Dual Modes: Free switch between "grid-following" (bidirectional grid energy exchange) and "grid-forming" (simulates virtual synchronous generator for isolated grid support).
- Grid Regulation: Impact-free soft grid-connection (THD <3%); coordinates with AGC/PMS for frequency regulation, AVC for reactive power/voltage control.
- Protection & Recording: Comprehensive protections (overvoltage/undervoltage/overcurrent/over-temperature/islanding/communication failure); fault recording in COMTRADE format.
- Communication: CAN/RS-485/RJ45/optical fiber ports; supports Modbus/IEC 61850/IEC 60870-5-103/GOOSE, delay <2ms.
5. Operation Procedures
- Grid-Following Startup: Power on upstream transformer → Close 1K MCB → Turn on NR1301 power → Power on battery → Close DC switch via EMS → Confirm no alarms/grid conditions met → Start PCS.
- Grid-Following Shutdown: Stop PCS via EMS → Open DC switch (confirm voltage 0) → Power off battery → Turn off 1K MCB → Trip HV breaker.
- Emergency Stop: Press "EMERGENCY STOP" button (for emergencies only).
6. Maintenance Requirements
- Preventive: Weekly (appearance, LEDs, air inlets/outlets); monthly (fixation, grounding); clean filters regularly; twice-yearly comprehensive check (clean components, cable insulation, grounding resistance).
- Fault Handling: Stop equipment/power off → Check components (modules, sensors, cables) per prompts; contact after-sales for unrepairable faults.
7. Safety Precautions
- Personnel: Only certified personnel allowed; trained in safety ops, first aid and safety gear (shoes, gloves, glasses, head protection) use.
- Electrical: No touch on energized terminals (DC voltage remains post-power-off); no PCB plug/unplug when energized; separate power/communication cables.
- Operation: No unauthorized parameter modification; no arbitrary AC/DC switch disconnection; no long-term overload.
8. Manufacturer Information
- Headquarters: 69, Suyuan Avenue, Jiangning, Nanjing 211102, China
- Manufactory: 18, Xinfeng Road, Jiangning, Nanjing 211111, China
- Contacts: Tel: +86-25-87178888; Fax: +86-25-87178999; Website: www.nrec.com/en