Protection&Control Transmission Line Protection Busbar Protection Transformer Protection Circuit Breaker Protection Generator Protection Feeder Protection Capacitor Protection Motor Protection Transfer & Synchronization Arc Protection
Digital Substation PCS-221S Merging Unit PCS-221 Merging Unit PCS-222 Circuit Breaker Controller PCS-9250 AC Electronic CT/VT
Automation PCS-9700 Automation System PCS-9700 HMI Software PCS-9705 Bay Control Unit PCS-9705S Bay Control Unit PCS-9799 Station Manager PCS-9799S Station Manager PCS-9710 Remote Terminal Unit PCS-9710S Remote Terminal Unit PCS-9794 Protocol Converter PCS-9785 Satellite-Synchronized Clock PCS-9882 Ethernet Switch PCS-9882Rx DIN Rail Managed Ethernet Switch PCS-9882XD Managed Ethernet Switch PCS-9884 Managed Ethernet Switch Supporting HSR and PRP MUX-2M/64 Communication Interface
Phasor Measurement PCS-997S Fault Line Locator PCS-996S-G Phasor Data Concentrator PCS-996 Phasor Measurement Unit
Disturbance Fault Recording PCS-996RC Disturbance Fault Recorder PCS-996R Disturbance Fault Recorder PCS-986 Disturbance Fault Recorder PCS-9013 DFR Management System
Stability Control System PCS-992 Power Stability Control System PCS-993 Out-of-Step Controller PCS-994 Frequency & Voltage Controller PCS-994S Frequency and Voltage Controller
Power Grid Monitoring and Control PCS-9000 Energy Management System PCS-9000 Distribution Management System
Configuration Tool PCS-Torch MOT Tool PCS-Studio Configuration Tool PCS-Explorer IED Configuration & Debugging Tool PCS-SCD Configuration Tool PCS-COMM Configuration & Debugging Tool
Accessories MD1501 Series Auxiliary Relays MD1701 Series Test Blocks MD1701S Test Block
FACTS PCS-9580 Static Var Compensator PCS-9583 Static Synchronous Compensator PCS-9570 Series Compensation PCS-9590 DC De-Icer PCS-9578 Controllable Shunt Reactor PCS-8200 Unified Power Flow Controller PCS-9571 Fault Current Limiter PCS-9564A Dynamic Voltage Restorer PCS-9569 Shore Power System
HVDC PCS-8600 UHVDC Converter Valve System PCS-9550 LCC-HVDC Control and Protection System PCS-8100 VSC-HVDC IGBT Valve PCS-9520 VSC-HVDC Control and Protection System PCS-9510 Cooling System PCS-8300 High-voltage DC Circuit Breaker PCS-9250 DC Electronic CT/VT
PV & Wind Power Grid-Connection PCS-9700 Renewable Energy SCADA PCS-9726 Generation Management Unit PCS-9700F Power Forecast System PCS-9700R AGC/AVC
Battery Energy Storage System PCS-9567MV-10000 Medium Voltage Skid PCS-9567MV-7000 Medium Voltage Skid PCS-9567MV-5000 Medium Voltage Skid PCS-9567MV-3500 Medium Voltage Skid PCS-9567-2500 Twin Power Conversion Systems PCS-9567-2500 電力変換システム PCS-9567-1750 Power Conversion System PCS-9567-1750 電力変換システム PCS-9567 Power Conversion System Vulnerability Disclosure Policy パワーコンディショナー脆弱性開示ポリシー
Microgrid PCS-9617MG Microgrid Controller
Static Frequency Converter PCS-9575 Static Frequency Converter
Protection,Automation&Control DMS EMS Stability Control & WAMS Digital Substation
HVDC & FACTS De-Icing Unified Power Flow Controller (UPFC) Series Compensation Static Synchronous Compensator(STATCOM) Static Var Compensator (SVC) LCC-HVDC Transmission VSC-HVDC Transmission
Renewable & Microgrid Energy Storage System Microgrid PV Generation SFC
Power Generation Pumped Storage Power Plant Nuclear Power Plant Hydro Power Plant Thermal Power Plant
Transmission System AC Transmission LCC-HVDC Transmission VSC-HVDC Transmission
Distribution System Distribution Network
Industrial Consumer Urban Track Traffic Electrified Railway Oil & Petrochemical Metals & Mining
HOME Solutions By industry Power Generation
NEWS
EVENT CALENDOR
CONTACT US
Hydroelectricity is the most widely used form of renewable energy in the world. It is expected to increase about 3.1% each year for the next 25 years. To keep up with the fast development of hydro power plant, NR Electric offers a series of solutions for hydro power plants to enhance production efficiency and improve generation safety.
NR provides the complete protection and control solutions for power generations, including generator, step-up substation and auxiliary electrical system. NR’s protection and control solution has been widely used in high capacity steam-turbine, gas-turbine and nuclear power generators.
Features
Unique generator-transformer unit protection for main and backup protection of generator-transformer units
High sensitivity can be gained during internal fault, while transient unbalance current can be avoided during external fault.
The motor protection solution covers the motor management of small capacity motors and the motor protection & control of PCC and MCC system from 380V to 600V.
The high speed transfer device is used in power plants to ensure the continuous and reliable power supply for busbars.
NR’s PCS-9150 advanced SCADA system is an integrated distributed platform used for the monitoring and management of the whole hydropower plants, including new built hydropower plants, retrofit hydropower plants and cascade hydropower plants.
The PCS-9150 features powerful predominance of dual power supplies for I/O modules, dual 100Mbps communication rate and high real-time capability, and has graphic configuration without compilation requirement.
Features
Embedded safety mechanism only receives qualified pre-defined network data packs and prohibits unauthorized connection to controller.
Redundancy: redundant LCU controllers, IO networks, HMI supervisory control networks, HMI interfaces, and power supplies, both controller and IO unit adopt dual power supply (AC220V or DC220V/110V wide voltage design; one model), optional redundant functions
Fully metal structure of controllers/IO modules, highly resistant to interference and with strong EMC
Millisecond level control cycle
Redundant 100Mbps control network and high-speed I/O network
SOE clock synchronization of 1ms
Disturbance-free update: disturbance-free update of controller during online operation
Excitation system is an important part of generator that is used to inject the exciting current into rotor to establish the magnetic field. The excitation system need to maintain the generator voltage level and is required to act on power system static and transient conditions.
NR provides microprocessor-based excitation system to improve generator performance and reduce maintenance costs. It offers comprehensive control strategies for different applications, such as power system stabilizer, optimum control or adaptive control, etc. It also can be customized to meet the various specifications of specific project. The current rating is available from 100A up to 7000A and the voltage rating is available from 100V up to 700V.
Features
Easy for upgrading or repair.
Maintaining the normal operation of the excitation system by fault tolerant control
Dual sets or multiply sets configuration to improve reliability of the whole control system
Seamless coordination between operation curve and excitation loss protection
Providing accesses to SAS or RTU via Ethernet network ports and serial ports
Complete event recording function
Powerful fault and disturbance recording function