Protection&Control Transmission Line Protection Busbar Protection Transformer Protection Circuit Breaker Protection Generator Protection Feeder Protection Capacitor Protection Motor Protection Transfer & Synchronization Arc Protection
Digital Substation PCS-221S Merging Unit PCS-221 Merging Unit PCS-222 Circuit Breaker Controller PCS-9250 AC Electronic CT/VT
Automation PCS-9700 Automation System PCS-9700 HMI Software PCS-9705 Bay Control Unit PCS-9705S Bay Control Unit PCS-9799 Station Manager PCS-9799S Station Manager PCS-9710 Remote Terminal Unit PCS-9710S Remote Terminal Unit PCS-9794 Protocol Converter PCS-9785 Satellite-Synchronized Clock PCS-9882 Ethernet Switch PCS-9882Rx DIN Rail Managed Ethernet Switch PCS-9882XD Managed Ethernet Switch PCS-9884 Managed Ethernet Switch Supporting HSR and PRP MUX-2M/64 Communication Interface
Phasor Measurement PCS-997S Fault Line Locator PCS-996S-G Phasor Data Concentrator PCS-996 Phasor Measurement Unit
Disturbance Fault Recording PCS-996RC Disturbance Fault Recorder PCS-996R Disturbance Fault Recorder PCS-986 Disturbance Fault Recorder PCS-9013 DFR Management System
Stability Control System PCS-992 Power Stability Control System PCS-993 Out-of-Step Controller PCS-994 Frequency & Voltage Controller PCS-994S Frequency and Voltage Controller
Power Grid Monitoring and Control PCS-9000 Energy Management System PCS-9000 Distribution Management System
Configuration Tool PCS-Torch MOT Tool PCS-Studio Configuration Tool PCS-Explorer IED Configuration & Debugging Tool PCS-SCD Configuration Tool PCS-COMM Configuration & Debugging Tool
Accessories MD1501 Series Auxiliary Relays MD1701 Series Test Blocks MD1701S Test Block
FACTS PCS-9580 Static Var Compensator PCS-9583 Static Synchronous Compensator PCS-9570 Series Compensation PCS-9590 DC De-Icer PCS-9578 Controllable Shunt Reactor PCS-8200 Unified Power Flow Controller PCS-9571 Fault Current Limiter PCS-9564A Dynamic Voltage Restorer PCS-9569 Shore Power System
HVDC PCS-8600 UHVDC Converter Valve System PCS-9550 LCC-HVDC Control and Protection System PCS-8100 VSC-HVDC IGBT Valve PCS-9520 VSC-HVDC Control and Protection System PCS-9510 Cooling System PCS-8300 High-voltage DC Circuit Breaker PCS-9250 DC Electronic CT/VT
PV & Wind Power Grid-Connection PCS-9700 Renewable Energy SCADA PCS-9726 Generation Management Unit PCS-9700F Power Forecast System PCS-9700R AGC/AVC
Battery Energy Storage System PCS-9567MV-10000 Medium Voltage Skid PCS-9567MV-7000 Medium Voltage Skid PCS-9567MV-5000 Medium Voltage Skid PCS-9567MV-3500 Medium Voltage Skid PCS-9567-2500 Twin Power Conversion Systems PCS-9567-2500 電力変換システム PCS-9567-1750 Power Conversion System PCS-9567-1750 電力変換システム PCS-9567 Power Conversion System Vulnerability Disclosure Policy パワーコンディショナー脆弱性開示ポリシー
Microgrid PCS-9617MG Microgrid Controller
Static Frequency Converter PCS-9575 Static Frequency Converter
Protection,Automation&Control DMS EMS Stability Control & WAMS Digital Substation
HVDC & FACTS De-Icing Unified Power Flow Controller (UPFC) Series Compensation Static Synchronous Compensator(STATCOM) Static Var Compensator (SVC) LCC-HVDC Transmission VSC-HVDC Transmission
Renewable & Microgrid Energy Storage System Microgrid PV Generation SFC
Power Generation Pumped Storage Power Plant Nuclear Power Plant Hydro Power Plant Thermal Power Plant
Transmission System AC Transmission LCC-HVDC Transmission VSC-HVDC Transmission
Distribution System Distribution Network
Industrial Consumer Urban Track Traffic Electrified Railway Oil & Petrochemical Metals & Mining
HOME PRODUCTS Protection,Automation & Control Protection&Control Busbar Protection
The PCS-915IC centralized busbar relay provides comprehensive protection solution for various arrangements of all voltage levels. The default busbar arrangements include single busbar with/without section, double busbar with/without section, double busbar with transfer bus, breaker-and-a-half arrangement and ring-breaker arrangement. The relay provides flexible configuration of the busbar topologies to meet specific applications. Due to its extensive CT input and I/O capability, the PCS-915IC is capable to protect up to 25 feeders.
It provides fast and secure low impedance busbar protection with sub-cycle tripping time. Check zone and discrimination zone of differential protection are equipped in the relay to minimize the outage zone. Advanced and patented technologies are incorporated to improve sensitivity and security, such as weighted CT saturation detection method, DPFC current differential protection.
The PCS-915IC is compatible with IEC 61850 station bus and process bus applications. It supports IEC 61850-8-1 MMS, GOOSE and IEC 61850-9-2 Sampling Value. The RJ-45 faceplate port is provided for testing and setting, allowing for easier commissioning and maintenance.
Busbar current differential protection (87B)
Phase current differential protection
DPFC differential protection
Voltage control element
CT saturation inhibit
Check zone and discrimination zone
Bus coupler/section protection
Breaker failure protection (50BF)
Dead zone protection (50DZ)
Pole disagreement protection (62PD)
Switch-onto-fault protection (50SOTF)
Overcurrent protection (50/51)
Feeder protection
Breaker failure protection (50BF)
Dead zone protection (50DZ)
Pole disagreement protection (62PD)
Overcurrent protection (50/51)
Voltage and current drift auto adjustment.
Frequency tracking.
Dynamic busbar replica
Isolator contact discrepancy alarm
CT failure supervision
VT failure supervision
Self diagnostic
Event recorder including 1024 change-of-binary-input events, 1024 supervision events and 1024 device logs
Disturbance recorder including 32 disturbance records with waveforms (The format is compatible with COMTRADE.)
Clock synchronization using IRIG-B, SNTP, PPS (Pulse-Per- Second) and PPM (Pulse-Per-Minute)
Up to four 10Base-T/100Base-TX copper Ethernet ports using IEC 61850, DNP3.0 or IEC 60870-5-103 over TCP/IP
Up to two 100Base-FX optical Ethernet ports using IEC 61850, DNP3.0 or IEC 60870-5-103 over TCP/IP ( Sharing two copper Ethernet ports)
Two RS-485 serial ports using IEC 60870-5-103
One RS-485 serial port for clock synchronization
Optional Sampling value and GOOSE communication module with 32 optical Ethernet ports using IEC 61850-9-2 and IEC 61850-8-1 GOOSE
HMI interface with large-size LCD and 9-button keypad on the front panel
One front RJ-45 port for testing and setting
One RS-232 or RS-485 rear port for printer
Language selection – English + selected language
Assistant software - PCS-Explorer