PCS-9691 Management Relay
  • The PCS-9691 relay is a protection, control and monitoring unit for various applications (such as overhead line, underground cable, transformer and capacitor etc.) on solidly grounded, impedance grounded, Peterson coil grounded and ungrounded system. The PCS-9691 features a high performance functional library, programmable logic, configurable I/O and integrated frequency-tracking. 

    The PCS-9691 is designed based on advanced multiprocessor platform, fully complying with IEC 61850 station bus, supporting IEC 61850-8-1 MMS.


  • Protection Control Monitoring Communcation
    • ŸSix-stage phase overcurrent protection(50/51P)

    • ŸFour-stage directional phase overcurrent protection (67P)

    • ŸSix-stage neutral/ground overcurrent protection(50/51N, 50/51G)

    • ŸFour-stage directional neutral/ground overcurrent protection(67N/G)

    • ŸTwo-stage negative-sequence overcurrent protection (46)

    • ŸThermal overload protection for alarm/trip (49)

    • ŸBroken conduct detection (46BC)

    • ŸBreaker failure element (50BF)

    • ŸDead zone protection (50DZ)

    • ŸUndercurrent protection (37)

    • Restricted earth fault protection (64REF)

    • ŸTwo-stage phase-ground or phase-phase undervoltage protection (27)

    • ŸTwo-stage phase-ground or phase-phase overvoltage protection (59)

    • ŸTwo-stage ground overvoltage protection (59G)

    • ŸOne-stage negative sequence overvoltage protection (47)

    • ŸFour-stage under-frequency protection (81U)

    • ŸOver-frequency protection (81O)

    • ŸFrequency rate-of-change protection (81R)

    • ŸDirectional power protection (32)

    • ŸFour-shot three-pole auto-reclosing (79)

    • ŸSynchronism check for manual closing and auto- reclosing (25)

    • ŸSwitch onto fault logic (SOTF)

    • ŸCold load pickup logic (CLP)

    • ŸMechanical protection (MR)

    • ŸFault location (FL)

    • ŸVoltage and current drift auto adjustment

    • ŸRemote/Local control

    • ŸLock/unlock logic

    • ŸFace plate control button

    • ŸTripping circuit supervision (TCS)

    • ŸVoltage transformer supervision (VTS)

    • ŸCurrent transformer supervision (CTS)

    • ŸCircuit breaker status monitoring

    • ŸSelf supervision

    • ŸUp to two 100Base-FX ports with IEC 61850-8-1 MMS for non-time-critical message, IEC 60870-5-103 over TCP/IP or DNP 3.0

    • ŸOne RS-485 rear port with IEC 60870-5-103 or Modbus

    • ŸOne RS-485 rear port for clock synchronization

    • Ÿ1 faceplate RJ45 port for testing and setting

    • ŸClock synchronization via pulse per second, IRIG-B and SNTP

    log on
    phone:
    password:
    Code:
    Register
    Register
    phone:
    password:
    E-mail:
    company:
    name:
    country:
    Code:
    Previous:PCS-9613S Differential Relay Back to list

    © Copyright NR Electric Co., Ltd.
    All Rights Reserved.

    About us Service & Support Company Training Contact Us

    Solutions Power Generation Transmission System Distribution Network Industrial Consumer

    Products Protection,Automation&Control FACTS HVDC Renewable & Microgrid